Cannot scan with Error 2274021 Coil Fault - Short Circuit A multicoil bias fault was detected due to coil
Symptom
Cannot scan with HNS coil with Error 2274021 Coil Fault - Short Circuit A multicoil bias fault was detected See Long Description Cannot scan with HNS coil with the error shown below logged. Mon Mar 1 09:22:21 2010 Error: 2274021 Host: WBH_RAD_MR11 Process: NSP File: SCP:RfHubCanHWO::RfBias Line: 4080 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Spin Echo Coil: HNS CTL123 Scan: 4637/1 Coil Fault - Short Circuit A multicoil bias fault was detected. Connector: Port 2 (P2) Channels faulted: 0x100 First channel: 9 of 32, counting from 1 Fault value: -4777 mV, Channel: 9-> Mon Mar 1 09:28:02 2010 Error: 2274021 Host: WBH_RAD_MR11 Process: NSP File: SCP:RfHubCanHWO::RfBias Line: 4080 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Spin Echo Coil: HNS- CTL12 Scan: 4637/1 Coil Fault - Short Circuit A multicoil bias fault was detected. Connector: Port 1 (P1) Channels faulted: 0x100 First channel: 9 of 32, counting from 1 Fault value: -4840 mV, Channel: 9->
Error message
2274021 Coil Fault - Short Circuit A multicoil bias fault was detected See Long Description Error: 2274021 Host: WBH_RAD_MR11 Process: NSP File: SCP:RfHubCanHWO::RfBias Line: 4080 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Spin Echo Coil: HNS CTL123 Scan: 4637/1 Coil Fault - Short Circuit A multicoil bias fault was detected. Connector: Port 2 (P2) Channels faulted: 0x100 First channel: 9 of 32, counting from 1 Fault value: -4777 mV, Channel: 9
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
- Component
- 2417327 12 Channel TORSO Coil 1.5T 12 CHANNEL BODY ARRAY COIL 2417327 COIL ASM 2417328 SYSTEM CABLE 2377425–3 PHANTOM KIT
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.