GE Healthcare · CTLightSpeed244634260140019244540

LightSpeed RT16 & RT16 Xtra and Vision

Symptom

Attention: The Scanning Hardware is not available. Please see long description. Attention: The Scanning Hardware is not available, please wait for the hardware reset successfull status posted in the feature status area on the right monitor. If the hardware reset fails, then reset the scan hardware from the Service Desktop System Resets button.

Error message

Error: 244634 Subsystem State; DCB:down, CCB:down, TCB:down, JEDI:down, TGP/ORP:down, DEVICES:up. GOC6 version All Down except Devices See Long Description Mon Dec 8 14:32:41 2008 Error: 244634 Host: CTUH07 Process: fwmgr File: fwmgr_utils.c Line: 677 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Subsystem State; DCB:down CCB:down TCB:down JEDI:down TGP/ORP:down DEVICES:up . The error above is from a GOC6, devices up is new and this stands for new feature like intergrated injector which has not been release at this time ( 12/23/2008)

Error: 260140019 HARD RESET through serial connection failed. see long desription for complete error Sat Oct 24 12:57:29 2009 Error: 260140019 Host: DTHCTGE01 Process: device_control File: device_control_proto.cxx Line: 157 HARD RESET through serial connection failed. some controllers(TGP, ORP, IPC, PROP, PSC) do not response to ping.

Error: 244540 Scan Seq Id: 0 Immediate Request cannot be honored since the firmware is in the DOWN state See Long Description for complete error Sun Sep 26 08:36:46 2004 Error: 244540 4 000ctge04 fwmgr FwMgrEventHandler.c 1517 Running diagnostic: Scan Data Path Functional Funct

Applies to

Models
LightSpeed
Product
LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2404320 CONSOLE INTERCOM PRESCRIBED-TILT HUB See Long description for details Part #: 2404320 Part Type: GP CONSUMABLES Part Weight: 21.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: CONSOLE INTERCOM PRESCRIBED-TILT HUB FRU: Yes Status: Orderable Comments: ** FE ASSIST ** CT/Pet Discovery systems must use 2404320. Recommended for CT Systems to order 2404320-2 , to avoid gantry lights being displayed when console is shut down. FMI 25407 or 22918 must be loaded prior to using the 2404320-2. (212001261 10/21/08) Added per VCT RSPL, ms13452 041209 __Set as Critical Part for Product CT_VCT, ms04278, 05Oct14
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues