Pular para o conteúdo principal
GE Healthcare · CTBrightSpeedVCT26000777127259260007940

BrightSpeed HPower, Delight, Velocity or MERI HPower

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260007771 DAS Single Card Communication Error See LD for complete error Error: 260007771 DAS Single Card Communication Error (could be MDAS or GDAS) MDAS: Mon Apr 17 08:16:46 2006 Error: 260007771 Host: orp Process: orp_subsys File: CnvBoardInterface.cc Line: 863 Mon Apr 17 08:16:45 2006 Host : Das Ermes # : 260007771 Exception Class : Soft Severity : Sec/Soft File : CnvBoardInterface.cc Line# : 863 Function : No System Function Reported Scan Type : None/Unknown Scan: 1094/2/0 M-DAS Single Card Communication Error. See Following Error Message for Converter Card List Board:19 Command: State Query Status: Communication timeout - no response. GDAS: Sat Aug 16 14:08:17 2008 Error: 260007771 Host: orp Process: orp_subsys File: CnvBoardInterface.cc Line: 863 Sat Aug 16 14:08:16 2008 Host : Das Ermes # : 260007771 Exception Class : Secondary Severity : Sec/Soft File : CnvBoardInterface.cc Line# : 863 Function : No System Function Reported Scan Type : Scout Scan: 27259/1/1 Converter Board Single Card Communication Error.^C See Following Error Message for Converter Card List Board: 81 Command: State Query Status: Communication timeout - no response.

Error: 260007940 A calibration re

Applies to

Models
BrightSpeed, VCT
Product
BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues