Grinding noise coming from the table while driving cradle in or out.
Symptom
Grinding noise coming from the table while driving cradle in or out. Table may move slower than normal. Customer may hear a grinding noise coming from the table while driving cradle in or out. Table may move slower than normal.
Error message
Error: 260115244 MTCB cradle moving direction error See the Long Description for the complete error code Thu Dec 28 10:59:18 2006 Error: 260115244 Host: tgp Process: tgp subsys File: mtcb cradle monitor.c Line: 823 Thu Dec 28 10:59:18 2006 Host : Table Sub-System Ermes # : 260115244 Exception Class : Secondary Severity : Pri/Soft File : mtcb cradle monitor.c Line# : 823 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 MTCB cradle moving direction error. Possible Encoder, cabling or MTCB board issue. Current Speed = -7300 Target Speed = 75000 Target Position = 1703000 Current Position = 101663
Applies to
- Models
- LightSpeed
- Product
- LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT