MAC00019 PDS Water Flow alarm due to internal flow restriction in Sumitomo Compressor.
Symptom
MAC00019 PDS Alarm Compressor water supply fault caused by water flow or temp being out of spec. The OnWatch engine has determined that the water supply to the coldhead compressor from the chiller is out of specifications. The water flow or water temperature parameter is out of specifications. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service. This is an automated alarm generated by the OnWatch program. An algorithm was run on the data uploaded from the MM3 into Insite2. The data shows that the water flow or water temperature values are out of specifications, The OnWatch engine algorithm used the engineering specifications supplied by the manufacture of the compressor, Sumitomo. This alarm needs to be resolved to extend the Coldhead and compressor lifespan.
Error message
MAC00019 PDS Alarm Compressor water supply fault caused by water flow or temp being out of spec The OnWatch engine has determined that the water supply to the coldhead compressor from the chiller is out of specifications. The water flow or water temperature parameter is out of specifications. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service.
Applies to
- Product
- Magnet Compressor Sumitomo. Parts information can be found in the Long Description. Static Pressure Dual Stage (4k):232 to 239 psig (16.3 to 16.8 kgf/cm^2)(1.6 to 1.65 MPa) Static Pressure Single Stage (HFO) and 10K:210 to 217 psig (14.8 to 15.3 kgf/cm^2)(1.45 to 1.50 MPa) Dynamic Pressure:319 to 333 psig (21.4 to 23.5 kgf/cm^2)(2.10 to 2.30 MPa) Compressor H2O Cooled 10K: 2188440-2 changed from T3487RT Compressor H2O Cooled 4K: 2188440-2 changed from T3487RT Compressor Air Cooled 4K: 2166592 changed from T3487RY Adsorber: 2172241 Supply Line 20M: 2154502-2 changed from T3487RJ Return Line 20M: 2154505-2 changed from T3487RK Supply Line 6M: * NO LONGER EXISTS IN ePDM , (Jim Cox 10/5/2007)* T3487RL Return Line 6M: 2154505 changed from T3487RM Static Pressure Dual Stage (4k):232 to 239 psig (16.3 to 16.8 kgf/cm^2)(1.6 to 1.65 MPa) Static Pressure Single Stage and 10K:210 to 217 psig (14.8 to 15.3 kgf/cm^2)(1.45 to 1.50 MPa) Dynamic Pressure:319 to 333 psig (21.4 to 23.5 kgf/cm^2)(2.10 to 2.30 MPa)
- Component
- SecondOpinion Part Number 2188440-2 Sumitomo CSW Series 4K and 10K Compressor. The Sumitomo 4K and 10K Compressor is the same Unit. Sumitomo compressor 2188440-2 is the same for both 10K and 4K Sumitomo cryo-cooler systems. See Long Description for FEMC Comments and Resolution concept for Second Opinion requirements before ordering this part. See comments in Resolution concept for Second Opinion requirements before ordering this part. FEMC Comments: FLS - COMPRESSOR USED ON SHI 10K SYSTEM REPLACES 2188440 PER PCN 188657. COMPLETELY INTERCHANGEABLE AND BOTH CAN BE COMBINED IN THE SAME POOL PER G. BUTLER 2-14-00, A. MASCH FOR GREEN SOURCE DIRECTLY FROMSUMITOMO JAPAN +++ For hour meter issues please order - 2191112-8. +++ *** 2ND OPINION NOTES *** This part has been identified as one requiring second opinion approval before ordering due to one or more of the following reasons: High cost. For approval: Americas - Contact: OnLine Center or your ZSE Europe - OnLine Center or your ZSE Asia - Contact the OnLine Center or your Technical Support. 212002950 April 28, 2008.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.