GE Healthcare · CTDiscovery26010500450364260118419
Scanner Hardware Stopped Scan.
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260105004 (20-0270) Vbias too low. Focal spot width and position affected Please see the Long Description for full error Sat May 8 10:16:13 2010 Error: 260105004 Host: orp Process: orp subsys File: gen exec.cxx Line: 2792 Sat May 8 10:16:12 2010 Host : Jedi Ermes # : 260105004 Exception Class : Secondary Severity : Pri/Soft File : gen exec.cxx Line# : 2792 Function : No System Function Reported Scan Type : Axial Scan: 50364/1/1. (20-0270) Vbias too low. Focal spot width and position affected Error: 260118419 Width Bias Control Voltage were out of range. It was 10% under prescribed voltage. See long description Sun Sep 6 17:16:40 2009 Error: 260118419 Host: orp Process: orp_subsys File: genJediSC.cxx Line: 1887 Sun Sep 6 17:16:38 2009 Host : On-Board Rotating Processor Ermes # : 260118419 Exception Class : Secondary Severity : Sec/Soft File : genJediSC.cxx Line# : 1887 Function : No System Function Reported Scan Type : Scout Scan: 6694/1/1 Width Bias Control Voltage were out of range. It was 10% under prescribed voltage. Where Technique: kV:120 mA:10 FS(1:S 2:L 4:XL):1 1 Point ExpTime(mS):2785 Rotor Speed (2:LOW 4:HIGH):2 GenOptions:0x8 and Freq: 1100(Hz)
Applies to
- Models
- Discovery
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- D3701T : PERSEUS TUBE UNIT - Used on CT750 HD See Long Description for details. Part #: D3701T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PERSEUS TUBE UNIT (GREEN) FRU: Yes Status: Orderable Comments: Per HDVCT RSPL, 212008898, 8/19/08. ** FE ASSIST ** Important to have adequate HV oil in the HV Wells. Making sure some oil does overflow when inserting Candle stick. (212001261 4/6/09)
- Area
- CT