Intermittent Scan Abort, No laser lights with Axial Errors.
Symptom
Intermittent Scan Abort, No laser lights with Axial Errors. See LD for more details Intermittent Scan Abort, No laser lights with Error: 183911 Axial HOME value TIMEOUT Fault Error: 183946 Axial Encoder Feedback Error Error: 184181 Number of offsets acquired does not match estimate of number of offsets generated Error: 183921 183944 Intermittent Scan Abort errors. Intermittently when laser light button is pushed the gantry spins but the lights never come on. Error: 183911 Axial HOME value TIMEOUT Fault. HW/SW Error: Retry Rx to verify probable gantry hardware problem. Error: 183921 Axial conditions at FAULT Error: 184181 Number of offsets acquired does not match estimate of number of offsets generated HW ERROR: Possible hardware problem. Offsets generated (estimate): -4904 Difference Between Generated and Acquired: 9810 Test Margin: 12 Triggers Error: 183944 Axial Encoder Feedback Error Encoder counts dropped during scan, may result in rotated images. Check images for proper orientation. Call Service. Error: 183946 Axial Encoder Feedback Error Accumulated counts measured since last re-reference were 33350 different than expected. (tolerance = 30 counts) Probable cause: faulty axial encoder Possible cause: faulty axial control board.
Error message
Error: 183911 Axial HOME value TIMEOUT Fault See Long Description for complete error Tue Nov 15 07:01:52 2005 Error: 183911 Suite: CT27 Host: STC Process: Axial File: ax_error.c Method: No Method Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 65001/11/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 07:01:50:045 Log Series: 1014 Axial HOME value TIMEOUT Fault. HW/SW Error: Retry Rx to verify probable gantry hardware problem.
Applies to
- Models
- HiSpeed
- Product
- HiSpeed CT/i 4.X HiSpeed CT/i 4.x with Zeus HSA Gantry and SGI Indigo Console HiSpeed CT/i with:HSA GANTRY CT/I (RHAPSODE) CONSOLE (Indigo Computer) Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-296854P2 Encoder - used on HSA/CTi/1.X gantries as the Axial Encoder and on Zeus Tables as the Elevation Encoder. See Long Description for part details Part #: 46-296854P2 Part Type: GP CONSUMABLES Part Weight: 0.88 LBR Repairable: No Returnable: No Hazardous Material: N Description: ELEVATION ENCODER FRU: Yes Status: Orderable ICV/Transfer Price: 104.55 USD /Each List Price: 815.40 USD /EACH Comments: FLS - ADDED PER PCN 189960. MS4636 4/22/97 & PCN 184587 MS03330 ** FE ASSIST ** Axial encoder HSA/CTi/1.X mounts on Axial Motor. (212001261 8/5/08) Part #: 46-296854P2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Axial Encoder FRU: Yes Status: Orderable Parts Offered as: Current: 46-296854P2 Used: Not Available Exchange: Not Available Comments: FLS - ADDED PER PCN 189960. MS4636 4/22/97 & PCN 184587 MS03330 5/5/97 COLLECTION OF DEFECTIVES START7/23/01 MS5277 FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA FE ASSIST: IN ORDER TO INCREASE REVENUE GLOBAL PARTS HAS CREATED A PROGRAM TO HARVEST PARTS FROM RENEWABLE RESOURCES. THESE PARTS OFFER DIRECT SAVINGS TO THE BUSINESSAND THE FIELD. ORDER THE "U" PART IF AVAILABLE. IF NO "U" USED PARTS ARE AVAILABLE CARES WILL CHANGE THE ORDER TOA NEW PART.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required