MRIQ Shading in Images Due to the Coil.
Symptom
MRIQ Shading in Images See long description Image Parameters Exam Description L-SPINE Series Description T1 SAG Anatomic Reference SN Scan Protocol Name Patient Weight (kg , Lb) 86 , 190 Image Type GE Advantage Windows Image Format Rectangular Image Matrix (pixels) 512 Image Suite ID #GEMS Study number 3128 Series number 3 Image number 6 Series Date & Time Nov 19, 1998 9:41:41 AM Image Date & Time Nov 19, 1998 9:41:41 AM Contrast information NO C Display FOV (mm) 300 Slice Thickness (mm) 4.0 Magnet Strength (Gauss) 15000 Number of excitations 2.0 Number of echoes 1 Flip Angle for GRASS(°) 90 TR (ms) 500 TI (ms) 0 TE (ms) 13 TE2 (ms) 0 Center Freq.(0.1Hz) 638915050 Auto Center Freq(0.1Hz) 638915050 Auto Trans.Gain(0.1dB) 170 Prescan R1 Analog 11 Prescan R2 Digital 15 SAT fat/water/none 0 Variable Bandwidth(Hz) 15.625 Nb of slices in this group 12 Phase contr. flow axis 0 Phase contr. velocity encoding 0 Prescan Flag Auto Prescan Succeeded Pulse Seq. Name fse-xl PSD Name FSE-XL Coil Name CTLBOT Slice Location (mm) -23.3 Scan Spacing (mm) 1.0 Recon. x (mm) -23.3 Recon. y (mm) -18.0 MRIQ Customer Image Library
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 2215261 1.5T Torso Phased Array Flex Coil See long description for Coil Shipping list and part numbers. This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. From the SIGNA® TORSO PHASED ARRAY COIL REV 2 DIRECTION 2218805 Documentation. To view the most recent appropriate and detailed documentation, click to go to SERVICE METHODS . 1.5T TORSO PHASED ARRAY COIL SHIPPING LIST
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.