GE Healthcare · CTBrightSpeed260118167
BrightSpeed Select, Delight Select or MERI Select
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260118167 (40-0104)Rotation current open load. Rotation board detected that no current is flowing to the motor. Wed May 12 13:54:03 2004 Error: 260118167 Host: orp Process: orp_subsys Wed May 12 13:54:02 2004 Host : Jedi Ermes # : 260118167 (40-0104)Rotation current open load. Rotation board detected that no current is flowing to the motor. Z6,Z7=7h,0h Code 40 Error code: 40-0104H Message/explanation: Rotation current open load Rotation board detected that no current is flowing to the motor. Potential cause: 1. Tube stator winding is open circuit: x-ray tube 2. Incorrect wiring (Open) 3. No DC bus on Rotation board 4. Phase shift capacitors not connected 5. Rotation board Recommended action/ Troubleshooting guide: Disconnect rotation-to-tube-stator cable and check stator windings impedance ohm). If open circuit, replace tube. Check wiring from rotation board to tube. Check DC bus voltage present on rotation board. Troubleshoot cables and fuses from Pi Filter board to rotation board Check that phase shift capacitors are correctly connected Run Rotation diagnostic (See diagnostic section). If test fails, replace Rotation board
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed Select, Delight Select or MERI Select Elite-16, Edge-8, Excel-4 HP_S_G16_G_HLT HP_S_G8_G_HLT HP_S_G4_G_HLT BrightSpeed Select or Delight Select (Hivalue Lite) 4/8/16 Slice Scanner BrightSpeed Delight Select Systems started to ship in first Quarter or 2009 with AIO (All in One) Console. AIO console uses HP8400 and NO DARC or IG's. Recon time is 6 FPS. If customer orders Fluoro option system requires one IG. The 16 FPS Upgrade in Not Available for Select systems. BrightSpeed Meri Select Systems ( Pancake Das ) started to ship in 3rd quarter of 2010, 4/8/16 Slice Scanner HiValue 16 Lite −−> BrightSpeed Elite Select HiValue 8 Lite−−> BrightSpeed Edge Select HiValue 4 Lite−−> BrightSpeed Excel Select BrightSpeed Select Scope: - 3.5MHu Solarix tube - JEDI 60 dc Lite - Modified NP Table Key Features: - 16x0.625mm(16x1.25) for Lite 16 - 8x1.25/8x2.5mm for Lite 4/8 - Rotation Speed: 0.8 s - Gantry: 2040mm width, 70cm Bore - Table: 1337@ISO-140mm scannable range - Recon: 3fps (w/o IG @ 2G Memory(4/8), 4G Memory(16)), optional: 6fps(w/ 1IG ) - Power: 42KW JEDI power See the attached Service Intro Planner for details Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2324118-3 VCT-JH4 Auxiliary Equipped. Aux Box See Long Description for details Part#:2324118-3 Part Type: GP CONSUMABLES Part Weight: 2.20 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT-JH4 AUXILIARY EQUIPED FRU: Yes Status: Orderable Comments: Set as Critical Part for Product CT_VCT, ms04278, 05Oct28 Added per VCT RSPL, ms13452 041205 Picture below
- Area
- CT