Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT26010107150018260101022

LightSpeed 5.X (80/100kW)

Symptom

"Scan hardware Stopped Scan" with DAS power errors. "Scan hardware Stopped Scan" with DAS power errors

Error message

Error: 260101071 The DCB has reset unexpectedly See Long Description for full error Error: 260101071 Host: orp Process: orp_subsys File: rcib_node_init.c Line: 376 Wed Jan 24 11:25:20 2007 Host : On-Board Rotating Processor Ermes # : 260101071 Exception Class : Secondary Severity : Pri/Soft File : rcib_node_init.c Line# : 376 Function : No System Function Reported Scan Type : None/Unknown Scan: 50018/1/0 The DCB has reset unexpectedly. The ORP has successfully reconnected to sub-system. Reason for reset as reported by CPU: External signal source. CPU reset register: 0x80 Node status: 0x382 State flags: 0x9800e82

Error: 260101022 Communications between the DCB sub-system and ORP have been lost See long description for full error Thu Jan 1 11:20:48 2009 Error: 260101022 Host: orp Process: orp_subsys File: rcib_init_state.c Line: 267 Thu Jan 1 11:20:47 2009 Host : On-Board Rotating Processor Ermes # : 260101022 Exception Class : Abort Severity : Primary File : rcib_init_state.c Line# : 267 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Communications between the DCB sub-system and ORP have been lost. Attempting to establish communications.

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5340738 (replaces 2359114) HPOWER GANTRY FAN AND HARNESS used on 5.x gantry See Long Description for details This fan for BrightSpeed, HP100, HP60 and RT Systems. Part #: 5340738 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: GANTRY FAN AND HARNESS FRU: Yes Status: Orderable Comments: Per ECR 2091297, 212008898, 10/26/09. Part #: 2359114 <-- All GPRS stock is gone and this part is now obsolete Part Type: GP CONSUMABLES Part Weight: 8.82 LBR Repairable: No Returnable: No Hazardous Material: N Description: HPOWER GANTRY FAN AND HARNESS FRU: Yes Status: Orderable Comments: FLS - HPOWER GANTRY FAN AND HARNESS.ADDED PER THE HPOWER RSPL. EXPECTED M3 FOR THIS PROGRAM: FW19, 2003. MS20544 2/28/03.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues