TPS reset fails due to failed PHPS2.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2268913 The MCPDB in the PHPS has detected a power failure. May 16 Mon 09:49:55 2268913 NSP SCP:SriManager 3925 Exception Class: Unknown Severity: Unknown Function: Patient Handling: Control/Display PSD: Unknown Coil: Unknown Scan: -1/-1 The MCPDB in the PHPS has detected a power failure-> 2268871 The dock power cable is not detected at the PHPS. May 16 Mon 09:49:55 2268871 NSP SCP:SriManager 3889 Exception Class: Unknown Severity: Unknown Function: Patient Handling: Control/Display PSD: Unknown Coil: Unknown Scan: -1/-1 The dock power cable is not detected at the PHPS.-> 2274510 CFB detected that the PHPS is too hot. May 16 Mon 09:49:55 2274510 NSP SCP:CfbHardware 665 Exception Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Unknown Coil: Unknown Scan: -1/-1 CFB detected that the PHPS is too hot. Bad cable connection to PHPS or bad PHPS is the likely cause. 2274516 Serial Communication between CFB and MCPDB inside the PHPS is down. May 16 Mon 09:49:55 2274516 NSP SCP:SystemCanInterf 1215 Exception Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Unknown Coil: Unknown Scan: -1/-1 Serial Communication between CFB and MCPDB in
Applies to
- Models
- Optima
- Product
- Optima MR450W Wide bore magnet. Not Discovery750 or Discovery450.
- Software
- 21.0 Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750). Only for Optima MR450W (wide bore) systems. (Not to be used on Discovery MR450 or Discovery MR750).
- Component
- 5167111 Assembly Patient Handling Power Supply 2 for DVMR 5167111 Assembly, Patient Handling Power Supply 2
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.