Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCTHiSpeed11002

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Can't network send to remote locations. Can't network -send - to remote locations

Error message

Error: 11002 DCM low level error: Operation error (506): Operation error (117). See Long Description for complete error Thu Jun 29 15:51:06 2006 Error: 11002 Host: gelightspeed Process: dcserver File: dcscommon.c Line: 228 DCM low level error: Operation error (506): Operation error (117).

Applies to

Models
LightSpeed, VCT, HiSpeed
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Software
10MW44.4 for GOC6.5 LightSpeed VCT with Titan configuration. LightSpeed VCT Quatra 10MW44.X software 10MW44.4.V40_H_HS64_G_GTM This software is now obsolete, this site should be upgraded to 11HW12.5 software released via FMI 25427 10MW44.4 for GOC6.5 LightSpeed VCT with Titan configuration. Refer to SN10120810a, which can be found on the Distributed Technical CDROM/DVD, or online. Links to any needed documentation is found in the Product concepts as an attachment called "ProductDocumentLinks" This software release introduces the following options to the VCT systems with Titan configuration and GOC 6.5 console: Overlapped Reconstruction Prospective Multi Recon (PMR) Direct Multi Planar Reformat (DMPR) SmartView CD/DVD Media Viewer
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues