GE Healthcare · CTLightSpeedVCT260107215260107214
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260107215 Axial Motor Control (AMC) Logic could NOT position the Gantry See long description for full error Fri Jan 6 14:13:53 2006 Error: 260107215 Host: tgp Process: tgp_subsys File: amc_mgr.c Line: 1662 Axial Motor Control (AMC) Logic could NOT position the Gantry, Retry Rx to verify probable Gantry Balance or Brake or Encoder Hardware. Error: 260107214 Gantry Failed to Stop at Position XX degrees within XX.X seconds See Long Description for complete error Thu Sep 22 13:19:47 2005 Error: 260107214 Host: tgp Process: tgp_subsys File: amc_mgr.c Line: 3687 Thu Sep 22 13:19:47 2005 Host : Table Gantry Processor Ermes # : 260107214 Exception Class : Abort Severity : Primary File : amc_mgr.c Line# : 3687 Function : AXIAL CONTROL : Axial Control Scan Type : Scout Scan: 279/1/1 Gantry Failed to Stop at Position 90 degrees within 28.000 seconds. (AMC state:7 Cmd:24 CurPos:91.0) Retry Rx to verify probable Axial Drive or Gantry Balance or Brake or Encoder Hardware.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required