GE Healthcare · CTLightSpeedVCT244633260125034260125005
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
The table is frozen, will not move THE TABLE IS FROZEN/WILL NOT MOVE
Error message
Error: 244633 Table reports that Table Communication becomes down. Wed May 25 17:35:00 2005 Error: 244633 Host: ct01 Process: fwmgr File: fwmgr_events.c Line: 7301 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Table reports that Table Communication becomes down. Error: 260125034 Did not reboot TCB within 20sec. See Long Description for complete error Tue Aug 8 21:50:05 2006 Error: 260125034 Host: tgp Process: tgp_subsys File: ta_func_gt.c Line: 735 Tue Aug 8 21:50:04 2006 Host : Table Gantry Processor Ermes # : 260125034 Exception Class : Secondary Severity : Pri/Soft File : ta_func_gt.c Line# : 735 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Did not reboot TCB within 20sec. Error: 260125005 Table Communication - Watchdog timeout. See long description for complete error Wed Jan 17 08:33:42 2007 Error: 260125005 Host: tgp Process: tgp subsys File: ta callback gt.c Line: 296 Wed Jan 17 08:33:42 2007 Host : Table Gantry Processor Ermes _ : 260125005 Exception Class : Secondary Severity : Pri/Soft File : ta callback gt.c Line_ : 296 Function : SYSTEM COMMUNICATIONS : Table Communications Scan Type : None/Unkno
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5139590 Control assembly left side gantry. ( replaces part# 2256729 and 2330695 ) – used on H2 & HP gantry’s (LightSpeed 2.x, 3.x, 4.x, 5.x, 7.x ) FEMC info in Long Description. 5139590 Control assembly left side gantry. ( replaces part# 2256729 and 2330695 ) – used on H2 gantry’s (LightSpeed 2.x, 3.x, 4.x, 5.x, 7.x ) Part #: 5139590 Part Type: GP CONSUMABLES Part Weight: 4.41 LBR Repairable: No Returnable: No Hazardous Material: N Description: H POWER OPERATOR CONTROLS LEFT SIDE FRU: Yes Status: Orderable If part number 2330695 is ordered it will automaticaly cross to part 5139590 Old part info 2256729 Control assembly left gantry Part #: 2256729 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: CONTROL ASM LEFT H2 GANTRY FRU: Yes Status: Orderable
- Area
- CT
Full cause & step-by-step resolution