Pular para o conteúdo principal
GE Healthcare · CT18390814756399903984439453183921

Lightspeed 1.X - Octane

Symptom

"Scan hardware Stopped Scan" with Axial Errors. "Scan hardware Stopped Scan" with Axial Errors

Error message

Error: 183908 Axial velocity ACCEL tracking fault See the Long Description for the full error code Mon Aug 27 09:12:45 2007 Error: 183908 Host: STC Process: Axial File: ax_error.c Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 14756/2/1 Type: Helical Exception Level: Pri/Most Severe Time: 09:12:45:860 Log Series: 363 Axial velocity ACCEL tracking fault. current: commanded = 39990 mA current: D/A measured = 39844 mA PDU measured = 39453 mA (HW/SW Error: Retry Rx to verify probable Axial Driver or. Axial Encoder hardware problem.)

Error: 183921 Axial conditions at FAULT: See Long Description for complete error Mon Oct 17 08:26:48 2005 Error: 183921 Suite: SMCT Host: STC Process: Axial File: ax_error.c Method: No Method Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 28848/2/1 Type: Helical Exception Level: Pri/Most Severe Time: 08:26:47:775 Log Series: 141 Axial conditions at FAULT: velocity_fb = 2662 position_fb = 50389 Formatted data: 8100 100 8 7 1 0 1 1 101 1 0 2662 -12655275 13081394 2741 2582 134 133 0x019e38

Applies to

Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-327176G2 Axial Drive Motor used on HSA, CTi and 1.X (Large) LightSpeed gantry - NOT for 2.X or newer See Long Description for info and picture 46-327176G2 Axial Drive Motor used on HSA, CTi and 1.X (Large) LightSpeed gantry - NOT for 2.X or newer Part #: 46-327176G2 Part Type: GP REPAIRABLES Part Weight: 68.63 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: AXIAL DRIVE MOTOR W/EMC FILTER PLUG FRU: Yes Status: Orderable FLS - FE: PLEASE READ SERVICE NOTE # 1356 REGARDING BRUSH REPLACEMENT. BRUSH PART NO. IS2102012. MBELL 11/94 ---------------------------------------------------- 4/2/03- PEERLESS CAN NO LONGERSUPPLY. PULLY HUB IS NO LONGER AVAILABLE PER BONNIE O'CONNOR. MS12464 3/2004- PEERLESS CAN BUILD IF WE SUPPLY PULLEY HUB TO THEM (P/N 46-296157P1), AS BDIREQUIRES 100 PC MIN BUY. MS12464 INFO FOR POOL BUILD: PCN # 161803 CHANGED FRU LEVEL FROM 46-296158P1 (MOTOR ONLY) TO 46-327176G2 (MOTOR + PULLEY). PCN 189289 46-327176G1 REPLACED BY G2 PERPCN 189289. MS4636 2/9/95
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues