Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT26010010610362395103618552601001071044152010440260

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

ECG Trace fails to display on the console. See Long Description for more details. ECG Trace intermittently fails to display on the console, requiring a software reboot to recover. Problem seen after upgrading to 06MW03.4 software. The ECG trace works the first time after a reboot but after any interruption, the trace cannot be restored using the Gating BPM button.

Error message

Error: 260100106 The current gating status indicates a PVC occurred See long description Thu Oct 22 10:24:32 2009 Error: 260100106 Host: tgp Process: tgp_subsys File: scExternalGate.c Line: 1281Thu Oct 22 10:24:32 2009Host : Table Gantry Processor Ermes # : 260100106Exception Class : Secondary Severity : Pri/SoftFile : scExternalGate.c Line# : 1281Function : No System Function ReportedScan Type : Helical Scan: 1192/4/1 WARNING: The current gating status indicates a PVC occurred. Current gating signal time = 10362395 msLast gating signal time = 10361855 msDifference between current and last gating signal = 540 msCurrent median = 1000 ms

Error: 260100107 The current gating status indicates a LATE R-peak See long description Thu Oct 22 10:25:51 2009 Error: 260100107 Host: tgp Process: tgp_subsys File: scExternalGate.c Line: 1314Thu Oct 22 10:25:51 2009Host : Table Gantry Processor Ermes # : 260100107Exception Class : Secondary Severity : Pri/SoftFile : scExternalGate.c Line# : 1314Function : No System Function ReportedScan Type : None/Unknown Scan: 0/0/0WARNING: The current gating status indicates a LATE R-peak. Current gating signal time = 10441520 msLast gating signal time = 104402

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
2280889 Gantry Option Board GOB See Long Description for Details Part #: 2280889 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: GANTRY OPTION BOARD FRU: Yes Status: Orderable
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues