CT/e Dual, CT ProSpeed AII/FII Irix or Linux

Symptom

Scan Aborts with JEDI XG Error. Scout Scan Aborts with JEDI XG Error

Error message

Error 186416 (20-1001-23 ) HV ON was not activated by JEDI on Axial Scan after EXPCMD was activated by OGP Please see long description Error 186416 HV ON was not activated by JEDI on Axial Scan after EXPCMD was activated by OGP Sun Apr 24 09:56:13 2011 186416 1 CT01 tgp_out tgp_errors.c 288 Axial Scan Error. Code : 20-1001-23 Error detected by : OGP HV ON was not activated by JEDI on Axial Scan after EXPCMD was activated by OGP.

Applies to

Models
HiSpeed
Product
CT/e Dual, CT ProSpeed AII/FII Irix or Linux HiSpeed CT/e Dual CT Scanner System see long Description for sales information Product Name: CT/e Dual CT Scanner System Irix A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) N/A Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links: Drawing Print 2320306-2CCT : http://gemspdm.med.ge.com/ematrix/common/eLibDocument.jsp?type=type_DrawingPrint&name=2320306-2CCT&rev=9 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5126995-2 PROGRAMMED KV CONTROL BOARD P5.2 used on CTe,YMS (2230555-6,2230555-7) See Long Description Part #: 5126995-2 PROGRAMMED KV CONTROL BOARD P5.47_FRU Displaying Change-Up Data: Part "2230555-7" changed to "5126995-2" Part #: 5126995-2 Part Type: GP CONSUMABLES Part Weight: 0.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: PROGRAMMED KV CONTROL BOARD P5.47_FRU FRU: Yes Status: Orderable ====================== Parts Offered as: Current: 5126995-2 Harvested: Not Available Exchange: Not Available ------------------------------------------------------------------- From part # 2230555-6 ** FE ASSIST ** if no stock of the 2230555-6 use 5126995-2 (212001261 7/7/09) FLS - KV BD PER ASIA USE 2230555-7 DEPENDING OF SYSTEM IN PLACE , YOU HAVE NOW TO ORDER FOR ALL PRODUCT USING JEDI RAD (GERAD/SILHOUETTE/PROTEUSPLS ORDER # 2265276-3FOR CT USING GENERATOR # 2238776 PLS ORDER # 2265276-3FOR CT USING GENERATOR # 2227720 PLS ORDER # 2230555-7FOR CT HIGHSPEED LX/I, FX/I, DX/I, CT/E PLS ORDER # 2230555-7..MS27898 ------------------------------------------------------------------------------------ 2230555-7 PROGRAMMED KV CONTROL BOARD P5.2 Part #: 2230555-7 Part Type: GP CONSUMABLES Part Weight: 1.36 KGM Repairable: No Returnable: No Hazardous Material: N Description: PROGRAMMED KV CONTROL BOARD P5.2 FRU: Yes Status: Orderable Parts Offered as: Current: 2230555-7
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.