The low efficiency of the cryo-cooler circuit has been identified.MAC00001 PDS Alarm Magnet Efficiency Issue detected a…
The low efficiency of the cryo-cooler circuit has been identified.MAC00001 PDS Alarm Magnet Efficiency Issue detected a Magnet Performance Issue.Adjust the shield cooler compressor pressure to operati…
Symptom
MAC00001 PDS Alarm Magnet Efficiency Issue detected a Magnet Performance Issue, Magnet Pressure increasing and Heater Duty Cycle at 0%. The OnWatch engine has determined that the magnet efficiency is degrading,pressure is trending up and the Heater Duty Cycle (HDC) has been at 0% for an extended period of time. See long description. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive magnet service. This is an automated alarm generated by the OnWatch program. An algorithm was run on the data uploaded from the MM3 into Insite2. The data shows an upward trend in the magnet pressure, which has now reached a trip point of over 4.25psi. The Heater Duty Cycle (HDC) has been at 0% for over 5 days. The OnWatch engine algorithm is used to filter out site power issues and water chiller issues, compressor should have continuous run time.. A sharp increase (spike) in the data is filtered out. This alarm should point to an issue with the efficiency of the cryo-cooler circuit.
Error message
MAC00001 PDS Alarm Magnet Efficiency Issue detected a Magnet Performance Issue, Magnet Pressure increasing and Heater Duty Cycle at 0%. The OnWatch engine has determined that the magnet efficiency is degrading, pressure is trending up and the Heater Duty Cycle (HDC) has been at 0% for an extended period of time. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive magnet service.
Applies to
- Product
- Magnet LCC 300. Software Version Concept should NOT be selected for Magnet Products Low Cryogen Consumption Serial number:Wxxx Field strength: 3.0 T He Vessel Pressure:>3 psig but <5 psig Shield Temp:< 55 Kelvin Coldhead Temp:> 3.8K but < 4.5K Recondenser Temp:> 4.2K but < 4.55K Delta Temp (Coldhead - Recondensor):> 0 but < 0.3K Min. LHe Fill Level: 60% Min. LHe Ramp Level: 100% Min. LHe Shim Level: 80% Helium Volume:1735 Liters Burst Disk:2349529 Burst Disk O-ring:46-281101P1 Baffle Assy: 2180818 Shim Lead Large 5/8:2173354
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.