GE Healthcare · CT200501547200001821200501533200600025

Lightspeed 1.X - Octane

Symptom

Scanner failed to initiate scan

Error message

Error: 200501547 A Communication Error has occurred in uifIpcSendRecvPriorityReconRequest See Long Description for Details Sat Mar 21 12:04:36 2009 Error: 200501547 Host: ct01 Process: scanRx File: uifIpcMgrScanRx.c Line: 9900 Function: Data Acquisition : OC Processing A Communication Error has occurred in uifIpcSendRecvPriorityReconRequest with seq_n um = 947 and status = 200001821

ERROR: 200501533 Event Router process with status: Timed out while attempting to receive a message.. See LD for variations of this error. ERROR: 200501533 Process Timed out while attempting to receive a message. Wed Feb 28 17:51:14 2007 Error: 200501533 Host: ct99 Process: scanRx File: uifIpcCommonFunctions.c Line: 2270 Function: No system function reported Service uif_scan_rx failed to receive message with event code 3141 from Event Router process with status: Timed out while attempting to receive a message. Below is another example of a different process that timed out: Fri Dec 30 10:03:25 2005 200501533 4 ctls16 reconMgmt uifIpcCommonFunctions.c 2269 Function: No system function reported Service uif_recon_mgmt failed to receive message with event code 3123 from Event Router process with status: Time

Applies to

Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.