GE Healthcare · CTBrightSpeed26011826050068
BrightSpeed HPower, Delight, Velocity or MERI HPower
Symptom
Can't scan or do warm up with Heat Exchanger PSI and Temp switches reporting open
Error message
Error: 260118260 ( 80-1422 ) Overpress or Blown fuse Error: 260118260 ( 80-1422 )Overpress or Blown fuse Wed Aug 17 17:37:03 2005 Error: 260118260 Host: orp Process: orp_subsys File: gen_exec.c Line: 2161 Running: System Reset Wed Aug 17 17:36:57 2005 Host : Jedi Ermes # : 260118260 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2161 Function : No System Function Reported Scan Type : None/Unknown Scan: 50068/1/0 (80-1422)Overpress or Blown fuse. Z6,Z7= 0h,0h Error: 110-0903h tube exceeded 92deg C (possibly 70deg C ?) See LD 110-0903h tube exceeded 70deg C Error code: 110-0903H Code 110 Message/explanation: Tube exceeded 70°C Tube temperature switch detected open Potential cause: X-ray tube too hot; normal error Cooling problem Wiring problem Sensor problem (Tube) Rotation board Recommended action/ Troubleshooting guide: Wait until tube cools down for error clearance. Troubleshoot tube cooling system (if applicable) If error persists, short circuit the sensor feedback (between pins 15 and 16 on rotation board connector J2) If error disappears check cabling to tube and tube thermal switch state. If no, replace rotation board
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required