GE Healthcare · CTLightSpeedVCT260100084260100052
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260100084 Final Exposure Command Scan Type : Scout Scan: See Long Description Mon Dec 6 16:34:56 2010 Error: 260100084 Host: tgp Process: tgp_subsys File: scTrigSeqActions.c Line: 1726 Mon Dec 6 16:34:56 2010 Host : Table Gantry Processor Ermes # : 260100084 Exception Class : Abort Severity : Primary File : scTrigSeqActions.c Line# : 1726 Function : XRAY GENERATION : Final Exposure Command Scan Type : Scout Scan: 7802/1/2 Timeout on Starting Offsets! Possible hardware problem. HW/OP/SW Error: Possible hardware, operator, or software problem. A list of hardware that is not ready for offsets follows: Error: 260100052 Axial was NOT ready See long description. Error: 260100052 Axial was NOT ready. Fri May 8 09:20:52 2009 Error: 260100052 Host: tgp Process: tgp_subsys File: scHdwRdy.c Line: 121 Fri May 8 09:20:51 2009 Host : Table Gantry Processor Ermes # : 260100052 Exception Class : Secondary Severity : Pri/Soft File : scHdwRdy.c Line# : 121 Function : No System Function Reported Scan Type : Scout Scan: 3650/1/2 Axial was NOT ready.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required