GE Healthcare · CTHiSpeed186449186437
HiSpeed Dual, ProSpeed FII Series
Symptom
Scanner Hardware Stopped Scan with slip ring communication errors Scanner Hardware Stopped Scan with slip ring communication errors.
Error message
Error: 186449 20-1001-16 Das trigger of one rotation, between g–pulse2, is under specification on helical scan. See logn description Tue Apr 28 15:51:56 2009 Error: 186449 Host: LINUX Process: tgp_out File: tgp_errors.c Line: 304 Helical Scan Error. Code : 20-1001-16 Error detected by : OGP DAS trigger of one rotation, between G-Pulse2, is under specification on Helical Scan. Error: 186437 OGP Event Error.Code : 20-1030-02 DAS Trigger was out of specification during scan. Or no DAS Trigger was detected after GANTINTREQ See Long Description Sun Sep 6 13:57:17 2009 Error: 186437 Host: LINUX Process: tgp out File: tgp errors.c Line: 395 OGP Event Error. Code : 20-1030-02 Error detected by : OGP DAS Trigger was out of specification during scan. Or no DAS Trigger was detected after GANTINTREQ
Applies to
- Models
- HiSpeed
- Product
- HiSpeed Dual, ProSpeed FII Series HiSpeed Dual, ProSpeed FII Series Product Name: Hispeed Dual ( Linux ) CT/Be2 A list of types. (a Product/hardware table) This console has an HP8000, HP8200, or HP8400 Computer (not GRE console) An On-site / Remote identification aid . (Example: check_config) HP Host computer A Table of options (included, optional, new introductions, …) HiSpeed Dual for China and Global B71402CA has the following as standard Options 1.5 sec fast scan, Power 200ma, Thichness 1mm, Raw data 5000, Image 100000 A list of Software that has run on this product (Product / Software Compatibility Table) With HP8000/8200 : • OS Version 4.5.15144980•Software Version 2.235165193 (except China)•Software Version 2.235172510 (for China only)•Patch 2.245179238•Patch 2.255197828•Patch 2.275267772 With HP8400 : •OS Version 6.2.95265475•Software Version 3.105270457•Patch 3.305267336•DVD Interchange 6.15270187•Patch 3.40 (See Note 8)5316222•DVD Interchange 7.05316345N/ Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links: Drawing Print 2320306-2CCT : http://gemspdm.med.ge.com/ematrix/common/eLibDocument.jsp?type=type_DrawingPrint&name=2320306-2CCT&rev=9 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required