BrightSpeed HPower, Delight, Velocity or MERI HPower

Symptom

Scanner keeps freezing up and would not go past scout acquisition Scanner keeps freezing up and would not go past scout acquisition.The below warning has also been seen in the operator message bar: "Not Enough Image Space Please Remove Images" Scanner keeps freezing up and would not go past scout acquisition The below warning has also been seen in the operator message bar: "Not Enough Image Space Please Remove Images"

Error message

Error: 9016 bad address format: See Long description for full error Tue Mar 11 04:47:36 2008 Error: 9016 Host: dgo_vct Process: netserver File: miscellaneous.c Line: 206 bad address format :

Applies to

Models
BrightSpeed
Product
BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
09HW30.4 For BrightSpeed Velocity See long Description 09HW30.4 For BrightSpeed Velocity {ctuser@ct01}[2] check_config sw_hw_string: 09HW30.4.HP_P_G16_G_GMV Software Collector Version 09HW30.4 p/n 5357076 5352829 - Class C (Tab# 182) 5357125 - Class M (Tab# 182)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.