GE Healthcare · CT368683288836961369603314436973
CT/e, CT Prospeed AI/FI Irix or Linux
Symptom
System will not boot to applications with HINV Error. HINV Error with NPR Error during boot-up. It can be any of the hardware shown in the screen shot.
Error message
usr/g/service/log/poweron.log file has an hinv error: Caution : we get diffarent hardware inventory vs. the default file. FLASH PROM version 4.1x See Long Description for a complete printout of the failing poweron.log file usr/g/service/log/poweron.log file has an hinv error: Caution : we get different hardware inventory vs. the default file. FLASH PROM version 4.1x IRIS% more poweron.log hinv test : Error *** PCI Device List *** - Adaptec SCSI : PCI Adapter ID (vendor 36868, device 32888) pci slot 1 - Adaptec SCSI : PCI Adapter ID (vendor 36868, device 32888) pci slot 2 - NPR : PCI Adapter ID (vendor 4277, device 36961) pci slot 5 - DBPCI : PCI Adapter ID (vendor 4277, device 36960) pci slot 6 - Adaptec SCSI : PCI Adapter ID (vendor 36868, device 33144) pci slot 4 - Serial Exp : PCI Adapter ID (vendor 4277, device 36973) pci slot 7 *** Caution : we get different hardware inventory vs. the default file. *** Please check the hardware enviroment. *** Diffarence(s) form the default file is(are) : *** 8c8 < FLASH PROM version 4.17 --- > FLASH PROM version 4.14 child process exited abnormally System Disk : Ok sc0d1l0: dsopen(sc0d1l0,0) dsopen(/dev/scsi/sc0d1l0,0) =>cp 1001a018, dsp 1001
Applies to
- Product
- CT/e, CT Prospeed AI/FI Irix or Linux See long description for sale information Product Name: CT/e Single CT Scanner: Irix Platform A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) 3.01 / 3.02 / 3.03 Linux CTe Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found in the attachment Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required