BrightSpeed HPower, Delight, Velocity or MERI HPower
Symptom
Cannot send exams to one particular remote host. see Long Description. Cannot send exams to one particular remote host. See the example below , here customer was not able to send to Nighthawk whereas image transfer is ok for other remote stations. Two remote hosts in blue having the same IP address. [insite@eimcgect2 ~]$ more /usr/g/ctuser/Prefs/SdCRHosts 10.167.52.21 ACV_ARCHIVE # 1 104 ARC1 CV PACS ARCHIVE 1 1 1 1 10.167.50.87 CAT_1 # 1 4006 eimcgect1 CTi 0 1 1 0 10.167.50.91 CT_AW # 1 4006 EIMCGECTAW01 No Comment 0 1 1 0 10.167.50.187 EFILM_REC # 1 4006 EIMCTWS08REC No Comment 0 1 1 0 10.167.50.40 GEPACS # 1 4100 GEPACS No Comment 0 1 1 0 10.067.44.37 MIA_RR3 # 1 3130 AE_MIARR3 No Comment 0 1 1 0 10.167.44.37 MIA_RR6 # 1 3140 AE_MIARR6 MIA BOX RM 6 0 1 1 0 10.167.50.34 GEPACS2 # 1 4100 GEPACS2 No Comment 1 1 1 0 10.167.44.37 MIA_NIGHTHAWK # 1 3140 AE_MIARR6 No Comment 0 1 1 0
Error message
Error: 11080 Connection Error See the Long Description for the full error code as seen in gesyslog Thu Dec 29 23:00:01 2005 Error: 11080 Host: wct1 Process: dcserver File: dcscommon.c Line: 242 Connection error: 39565 (EFILM-WHRA) as seen in DCSLOG MESSAGE from Process 1937>> Fri Apr 7 19:00:01 2006 (dcscommon.c:242) Connection error: 11283 (PACS_Live)
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required