GE Healthcare · CTLightSpeed
LightSpeed 4.X - GRE
Symptom
System fails to reconstruct images. System fails to reconstruct images
Error message
DARC /var/log/messages : timeout attempting to rsh to ig2 ( can be ig1 or ig3 ) See long description DARC /var/log/messages Aug 18 18:43:09 darc logger: is_IG_up 1 ig2 called Aug 18 18:43:09 darc is_IG_up:[recon_control:7973]: ig3 is up ( this will be typically 5 mins after start of DARC boot ) Aug 18 18:43:09 darc is_IG_up:[recon_control:7967]: ig1 is up Aug 18 18:43:10 darc is_IG_up:[recon_control:7970]: timeout attempting to rsh to ig2 ( this is ig2 failing to respond to DARC ) With no intervention DARC will retry to contact ig that failed to respond on fisrt attempt ( notice timestamps ) Aug 18 18:49:58 darc logger: is_IG_up 3 ig2 called Aug 18 18:49:58 darc mountd[3273]: authenticated mount request from ig2:855 for /usr/g (/usr/g) Aug 18 18:49:58 darc is_IG_up:[recon_control:7970]: ig2 is up ( ig2 up nearly 7 minutes after second start )
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required