Pular para o conteúdo principal
GE Healthcare · CTHiSpeed244521182101500911786016095615000

HiSpeed QX/i - Octane

Symptom

Scanner Hardware Reset Failed. See LD Scanner Hardware Reset Failed Hardware Failed to reset message appeared on monitor AFTER boot-up WITH Error:178568 Failed to establish socket connection to STC in 10 seconds and errors 244553 and 244554 and power up self test fails A, B, and 9 on STC CPU board The following errors were in the gesyslog Thu Jan 13 04:18:32 2005 Error: 178568 Suite: RP25 Host: SBC0 Process: fwmgr File: NBSSocket.m 1.9 Method: connectToTarget Line: 315 Failed to establish socket connection to STC in 10 seconds Thu Jan 13 04:18:32 2005 Error: 244553 Suite: RP25 Host: SBC0 Process: fwmgr File: HwSetUp.m 1.18 Method: hardReset Line: 429 The STC controller has failed to reset. Thu Jan 13 04:18:32 2005 Error: 244554 Suite: RP25 Host: SBC0 Process: fwmgr File: HwSetUp.m 1.18 Method: hardReset Line: 442 The reset failure of the OBC may be due to the reset failure of the STC. Also saw failures A, B, and 9 on the power-up test on the STC CPU .

Error message

Error: 244521 Scan Seq Id: 0 Timed out waiting for a CF reply. See long description for a sample error message. Fri Feb 26 10:30:19 2010 Error: 244521 Host: lightspeed Process: fwmgr File: Das.c Line: 3726 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Timed out waiting for a CF reply.

Error: 182101 Notify Verification TIMEOUT with OBC (uuid 192) (SW opening abort relay). See LD for complete error Wed Sep 20 08:39:00 2006 Error: 182101 Host: STC Process: Master Exc Handler File: exm_verify_wdog.c Line: 190 Function: No System Function Reported Scan: 50091/8/0 Type: None/Unknown Exception Level: Secondary Time: 08:39:00:905 Log Series: 724 Notify Verification TIMEOUT with OBC (uuid 192) (SW opening abort relay). HW/SW Error: Did not receive message from OBC local exception handler. Will need a Hardware Reset.

Error: 178601 Timed out waiting for CF query response See Long Description Mon Nov 23 12:59:34 2009 Error: 178601 Host: ls01 Process: fwmgr File: CF.c Line: 1910 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Timed out waiting for CF query response. Msg code sent to fw: 60956 Response message 

Applies to

Models
HiSpeed
Product
HiSpeed QX/i - Octane Always MDAS4 101I.2_HSQXIM5 101.4_HSQXIM4 HiSpeed QX/i - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 101I.2_HSQXIM5 101.4_HSQXIM4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
101I.2_HSQXIM5 See LD for ClassM & C 101I.2_HSQXIM5 used on HiSpeed (YMS) only Class M software - 2395173 or 2401759 (6 pack) Class C software - 2395172 or 2401759 (6 pack) Patch G.6 Mandatory FMI# 25363 (P/N 5136941)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues