GE Healthcare · Nuclear Medicine39638114809100008553
Unable to adjust VG rotor power supply - Maximum voltage reached
Symptom
Unable to adjust VG rotor power supply - Maximum voltage reached When applying PSDB solution KOID: 39638 and 114809 , FSE was unable to reach specs values. Analogue and Digital values was always out of limit. Sensheat provide always wrong low analogue -5V (reading aprox. -4.6 V) and digital 5V (reading aprox 4.7 V) Reading from DVM on input of DOC board voltage was over specification (> 5 V). Contributor 100008553 B.Certo February 14, 2011
Applies to
- Product
- VGH VG and VG Hawkey and Varicam
- Software
- VGH 6.0 VGH Acq 6.0 VG Acq 6.0 Part #: UGP001355 VG/DVG VER.6 KIT FOR SPARE PART (also see additional requirements below) Includes Software LSW000398 VG DVH HAWKEYE VER. 6 SW PACKAGE: Engineering Bill of Materials Name Description LSW000382 VG VH HAWKEYE Ver. 6 SW CD LSW000312 RCU for Dell 1400SC LSW000332 DISKETTE 1 SYSTEM LSW000403 Ver 6.0 Supplement 12 patch ver 6.0 build 7.5 (SN43633) LSW000426 VG Ver. 6 Motion and Worklist Patch.(SN43524) Also Includes: Software LSW000333 SOFTWARE PACKAGE FOR OLD COMPUTER VG: Engineering Bill of Materials Name Description LSW000011 DISKETTE 1 SYSTEM LSW000203 CKERMIT for GX200 LSW000022 SOFTWARE DELL ECU DISKETTE LSW000101 RCU for DELL 1300 ESW000637 HPC-HP 3COM LSW000404 DISKETTE 1 SYSTEM For HP NetServer Dell 2200 In addition VG requirements : UGP001583 VG Ver. 6.0 MUGA Patch LSW000490, FMI 40788 5195796 VG CoDe 2 Cold Spot, FMI 40805, CODE system only. 5169077 VG Software ver.6.0 Motion II ver. 2.0 patch 6.0P7 Service Note 43633 Optional: 5169169 Service Pack # 5169169 Q3 ver 2.0, SN43632
- Component
- P05560006F PDOC Power Connector, 6 Pos. Fem. 12AWG P05560006F PDOC Power Connector, 6 Pos. Fem. 12AWG *Detector (Imaging Detector) *Detector (Imaging Detector) *Detector (Imaging Detector)
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- After telnet remote boot of Genieacq SuperMicro computer there is no boot activity
- Xeleris T42 IBM laptop not booting from dock station
- During boot of Infinia NWSERVER process is using all the CPU time
- EISA Framing board does not fit on newer Millennium acquisition station PC's
- Infinia Hawkeye 4 Failing to start NM scan and X-Ray Daily QC Failing after Warmup
- Xeleris Database Occupied Disk Space Space Indicator (Pie Chart) does not display correct value.