GE Healthcare · CTLightSpeedVCTHiSpeed130436821304368113043680130436781302705413033392

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Localizer lines missing after scout is scanned. See Long Description for details. Localizer lines missing after scout is scanned The following are a list of PQRs and PSRs written to document this Issue: PSR 13043682 04MW44.1: Localizer issue PSR 13043681 HP60: Localizer issue PSR 13043680 04MW44.1: Localizer issue PSR 13043678 HP60: Localizer issue PQR 13027054 04MW13.7: Unable to adjust localizer lines PQR 13033392 04MW13.7: Scout and Show Localizer issue PQR 13034974 04MW44.1: Scout not viewable when localizer is attempted PQR 13035489 H4.2M4: Scout Image and localizer line not displayed after scout scan PQR 13036676 04MW44.1: Show localizer not working PQR 13036775 04MW44.1: Scout image and localizer issue PQR 13037188 HP60: show localizer scout images failed to display PQR 13040210 HP60: No show localizer image PQR 13042579 HiSpeed QX/i: the cut lines on the localizer image will only very breifly display and then disappear PQR 13047649 04MW44.9: Localizer lines are not showing up after scout PQR 13045218 H5: Localizer Issue For VCT refer to iTrak reports: 13043451 13043029 13044089 13049939 13050718

Applies to

Models
LightSpeed, VCT, HiSpeed
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required