LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Exam/Series/Image did not show up in the Patient List Select (image browser). See Long Description for Details Exam/Series/Image did not show up in the Patient List Select (image browser). The customer did a refresh of the browser and the images were then shown in the list. Selecting the images and trying to display them resulted in a message “No Valid Selection”. User scanned a series and the images were generated and displayed in the autoview view port. The issue is that the Exam/Series/Image did not show up in the Patient List Select (image browser). The customer did a refresh of the browser and the images were then shown in the list. Selecting the images and trying to display them resulted in a message “No Valid Selection”. Images did get put in the database but were not accessible by the customer. Reboot did not fix this problem
Error message
Error: 200281000 Description='AiM error: requestedService='Ex_Ser_Path_Rqst' message='Browser cannot find exams or series or images matching e/s/i request 1103/601'' Code=3 See LD for complete error Sat Dec 2 11:03:46 2006 Error: 200281000 Host: mhvct1 Process: visScript File: VavBrowserProxy.cxx Line: 567 Error reported: Class=VavBrowserProxy Method=answerToRequestCallback Location=VavBrowserProxy.cxx, 567 Description='AiM error: requestedService='Ex_Ser_Path_Rqst' message=' Browser cannot find exams or series or images matching e/s/i request 1103/601'' Code=3
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required