GE Healthcare · CT18280450080
Lightspeed 1.X - Octane
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 182804 The Gantry Display is NOT Initialized Properly See the LD for the full error code Error: 182804 The Gantry Display is NOT Initialized Properly Wed Feb 8 07:20:05 2006 Error: 182804 Host: ETC Process: Scan File: etc_in_mail.c 1.38 4/16/01 Line: 648 Function: No System Function Reported Scan: 50080/1/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 07:20:05:645 Log Series: 37 HW/SW error: Communication Problems with the Gantry Display. The Gantry Display is NOT Initialized Properly. (Scanning is NOT allowed if the Gantry Display is NOT Working)
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-296341G1 GANTRY DISPLAY ASSY. See LD for details Part #: 46-296341G1 Part Type: GP REPAIRABLES Part Weight: 5.91 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: GANTRY DISPLAY ASSY. FRU: Yes Status: Orderable Parts Offered as: Current: 46-296341G1 Harvested: Not Available Exchange: Not Available Comments: FLS - CLASS 1 FRU. PDV
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.