LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Cannot send exams to one particular remote host. see Long Description. Cannot send exams to one particular remote host. See the example below , here customer was not able to send to Nighthawk whereas image transfer is ok for other remote stations. Two remote hosts in blue having the same IP address. [insite@eimcgect2 ~]$ more /usr/g/ctuser/Prefs/SdCRHosts 10.167.52.21 ACV_ARCHIVE # 1 104 ARC1 CV PACS ARCHIVE 1 1 1 1 10.167.50.87 CAT_1 # 1 4006 eimcgect1 CTi 0 1 1 0 10.167.50.91 CT_AW # 1 4006 EIMCGECTAW01 No Comment 0 1 1 0 10.167.50.187 EFILM_REC # 1 4006 EIMCTWS08REC No Comment 0 1 1 0 10.167.50.40 GEPACS # 1 4100 GEPACS No Comment 0 1 1 0 10.067.44.37 MIA_RR3 # 1 3130 AE_MIARR3 No Comment 0 1 1 0 10.167.44.37 MIA_RR6 # 1 3140 AE_MIARR6 MIA BOX RM 6 0 1 1 0 10.167.50.34 GEPACS2 # 1 4100 GEPACS2 No Comment 1 1 1 0 10.167.44.37 MIA_NIGHTHAWK # 1 3140 AE_MIARR6 No Comment 0 1 1 0
Error message
Error: 11002 DCM low level error: Operation error (506): Operation error (117). See Long Description for complete error Thu Jun 29 15:51:06 2006 Error: 11002 Host: gelightspeed Process: dcserver File: dcscommon.c Line: 228 DCM low level error: Operation error (506): Operation error (117).
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required