LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Customer gets tube cooling delays on each scanning protocol. Customer gets tube cooling delays on each scanning protocol
Error message
Error: 245195 The tube cooling state data indicated an unusual ISD (7732166.783632). Scanning cannot proceed with the current tube state file. See long description for complete error Mon Nov 20 21:50:29 2006 Error: 245195 Host: lder Process: scanmgr File: tube_cooling.cxx Line: 169 Function: System Control : Scan Control Scan Type: Not scanning Scan: 50001/1/0 Scan Seq Id: 3 The tube cooling state data indicated an unusual ISD (7732166.783632). Scanning cannot proceed with the current tube state file. Error: 245194 reading the tube state file (elapsed time = -9999.000000). Resetting the tube state to HOT to reduce risk to the tube. ERROR: 245194 reading the tube state file (elapsed time = -9999.000000). Resetting the tube state to HOT to reduce risk to the tube. Fri Apr 22 07:45:10 2005 Error: 245194 Host: eastct2 Process: scanmgr File: tube_cooling.cxx Line: 111 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Error reading the tube state file (elapsed_time = -9999.000000). Resetting the tube state to HOT to reduce risk to the tube. Error: 245176 The call to the tubeCooled tube cooling library function failed. See long description for comp
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required