Pular para o conteúdo principal
GE Healthcare · CTBrightSpeed260107251260107800

BrightSpeed Select, Delight Select or MERI Select

Symptom

Gantry will not rotate or scan, alignment lights will not turn ON

Error message

Error: 260107251 Axial Motor Control (AMC) logic lost communication with the Axial Drive. See Long Discription for Details Error: 260107251 Axial Motor Control (AMC) logic lost communication with the Axial Drive. Mon Jul 19 07:41:43 2010 Error: 260107251 Host: tgp Process: tgp_subsys File: ds301.c Line: 828 Mon Jul 19 07:41:41 2010 Host : Table Gantry Processor Ermes # : 260107251 Exception Class : Secondary Severity : Sec/Soft File : ds301.c Line# : 828 Function : AXIAL CONTROL : Axial Communications Scan Type : None/Unknown Scan: 0/0/0 . Axial Motor Control (AMC) logic lost communication with the AXIAL drive (Comm Watchdog Failure)

Error: 260107800 DS301 CAN packet transmission error See long description Tue Oct 26 03:43:43 2010 Error: 260107800 Host: tgp Process: tgp_subsys File: ds301.c Line: 1019 Tue Oct 26 03:43:42 2010 Host : Table Gantry Processor Ermes # : 260107800 Exception Class : Secondary Severity : Pri/Soft File : ds301.c Line# : 1019 Function : AXIAL CONTROL : Axial Communications Scan Type : None/Unknown Scan: 0/0/0 . DS301 CAN packet transmission error. Number of send attempts: 3. Maximum allowed send attempts: 3.

Applies to

Models
BrightSpeed
Product
BrightSpeed Select, Delight Select or MERI Select Elite-16, Edge-8, Excel-4 HP_S_G16_G_HLT HP_S_G8_G_HLT HP_S_G4_G_HLT BrightSpeed Select or Delight Select (Hivalue Lite) 4/8/16 Slice Scanner BrightSpeed Delight Select Systems started to ship in first Quarter or 2009 with AIO (All in One) Console. AIO console uses HP8400 and NO DARC or IG's. Recon time is 6 FPS. If customer orders Fluoro option system requires one IG. The 16 FPS Upgrade in Not Available for Select systems. BrightSpeed Meri Select Systems ( Pancake Das ) started to ship in 3rd quarter of 2010, 4/8/16 Slice Scanner HiValue 16 Lite −−> BrightSpeed Elite Select HiValue 8 Lite−−> BrightSpeed Edge Select HiValue 4 Lite−−> BrightSpeed Excel Select BrightSpeed Select Scope: - 3.5MHu Solarix tube - JEDI 60 dc Lite - Modified NP Table Key Features: - 16x0.625mm(16x1.25) for Lite 16 - 8x1.25/8x2.5mm for Lite 4/8 - Rotation Speed: 0.8 s - Gantry: 2040mm width, 70cm Bore - Table: 1337@ISO-140mm scannable range - Recon: 3fps (w/o IG @ 2G Memory(4/8), 4G Memory(16)), optional: 6fps(w/ 1IG ) - Power: 42KW JEDI power See the attached Service Intro Planner for details Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues