GE Healthcare · CTLightSpeedVCT2601346221782460244633
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260134622 Cradle absolute encoder warning. See Long Description for details Mon Nov 5 21:53:29 2007 Error: 260134622 Host: tgp Process: tgp subsys File: gtcb cmc drv req.cxx Line: 1224 Mon Nov 5 21:53:29 2007 Host : Table Sub-System Ermes # : 260134622 Exception Class : Secondary Severity : Pri/Soft File : gtcb cmc drv req.cxx Line# : 1224 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle absolute encoder warning. current pos = 1782460 um, temp = 191 degC Error: 244633 Table reports that Table Communication becomes down. Wed May 25 17:35:00 2005 Error: 244633 Host: ct01 Process: fwmgr File: fwmgr_events.c Line: 7301 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Table reports that Table Communication becomes down.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5122207-2 ABSOLUTE ENCODER FOR CRADLE GT (replaces 5122207) See long description for details Part #: 5122207-2 ABSOLUTE ENCODER FOR CRADLE GT (replaces 5122207) Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: ABSOLUTE ENCODER FOR CRADLE GT FRU: Yes Status: Orderable Comments: This part is used in GT-1700mm and GT-2000mm tables. Not Available
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.