GE Healthcare · CTLightSpeedVCT26011201513070
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Customer was not able to remote tilt gantry. In many cases , gantry will tilt from the Gantry Controls.
Error message
Error: 260112015 The Gantry Touch Sensor FAULT ( error text varies ) See long description for error examples Error text varies. Tue Sep 4 10:28:17 2007 Error: 260112015 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr_gt.c Line: 9075 Tue Sep 4 10:27:02 2007 Host : Table Gantry Processor Ermes # : 260112015 Exception Class : Secondary Severity : Pri/Soft File : uif_table_tilt_mgr_gt.c Line# : 9075 Function : PATIENT ANATOMY POSITIONING : Tilt Drive Scan Type : None/Unknown Scan: 6891/2/0 The Gantry Touch Sensor FAULT. Gantry Sensors: BACK Touch Sensor Error(s). Gantry Controls are running in FAULT MODE. Operator's Console Remote Tilt button is DISABLED. Use local gantry controls to tilt the gantry Sat Nov 17 00:07:55 2007 Error: 260112015 Host: tgp Process: tgp subsys File: uif table tilt mgr gt.c Line: 13070 Sat Nov 17 00:07:54 2007 Host : Table Gantry Processor Ermes # : 260112015 Exception Class : Secondary Severity : Pri/Soft File : uif table tilt mgr gt.c Line# : 13070 Function : PATIENT ANATOMY POSITIONING : Tilt Drive Scan Type : None/Unknown Scan: 0/0/0 The Gantry Touch Sensor FAULT. Gantry Sensors: FORWARD Touch Sensor Error(s). Gantry Controls are running in FAULT MO
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5134416-2 Front Cover Sensor, Patient Tilt, Small, White N9 (for VCT Titan and HD VCT gantries) See Long Description Part #: 5134416-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Sensor Asm, Front Cover - White N9 FRU: Yes Status: Orderable Current : 5134416-2 Harvested : Not Available Exchange : Not Available Comments: Per HD VCT RSPL, 212008898, 7/14/08. 5134416 Front Cover Sensor, Patient Tilt, Small, 175mm long tail with bend for low profile cover routing (For VCT) See long decription for details Sensor, Patient Tilt, Small, 175mm long tail with bend for low profile cover routing Part #: 5134416 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Sensor, Patient Tilt, Small, 175mm long tail with bend for low profile cover routing FRU: Yes Status: Orderable Comments: Added per iTrak: 13056981. ms13452 060228
- Area
- CT
Full cause & step-by-step resolution