Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT26012200450147260132907

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Attention The detector is not at the proper temperature. see long description for more detail. Attention The detector is not at the proper temperature. If you wish to proceed with this scan select the "OK" button, however IQ may be degraded including image artifacts. Please contact GE Service

Error message

Error: 260122004 Gantry Fan failure detected - See error variations for different top gantry fans See Long Description for complete error. Tue Feb 13 01:30:38 2007 Error: 260122004 Host: tgp Process: tgp_subsys File: gantryThermalMgr.cxx Line: 1306 Tue Feb 13 01:30:38 2007 Host : Table Gantry Processor Ermes # : 260122004 Exception Class : Secondary Severity : Pri/Soft File : gantryThermalMgr.cxx Line# : 1306 Function : No System Function Reported Scan Type : None/Unknown Scan: 50147/5/0 Gantry Fan failure detected on fan Heater Blower Tue Feb 13 01:32:52 2007 Error: 260122004 Host: tgp Process: tgp_subsys File: gantryThermalMgr.cxx Line: 1306 Tue Feb 13 01:32:52 2007 Host : Table Gantry Processor Ermes # : 260122004 Exception Class : Secondary Severity : Pri/Soft File : gantryThermalMgr.cxx Line# : 1306 Function : No System Function Reported Scan Type : None/Unknown Scan: 50147/5/0 Gantry Fan failure detected on fan Right (Small) Booster Tue Feb 13 01:32:52 2007 Error: 260122004 Host: tgp Process: tgp_subsys File: gantryThermalMgr.cxx Line: 1306 Tue Feb 13 01:32:52 2007 Host : Table Gantry Processor Ermes # : 260122004 Exception Class : Secondary Severity : Pri/Soft File : gantryT

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.