Pular para o conteúdo principal
GE Healthcare · CTBrightSpeed20010700224527810443337000200107023244599

BrightSpeed HPower, Delight, Velocity or MERI HPower

Symptom

Console keyboard no longer functions in the scan prescription GUI on the left side screen butl still functions normally in other GUIs and on the right side screen. See long description Console keyboard no longer functions in the scan prescription GUI on the left side console screen. Keyboard will still function normally in other GUIs and on the right side console monitor screen. Keyboard may or may not beep when trying to type with it on the scan prescription GUI. System will still function and a graphic scan prescription can be done, but no scan parameters can be manually edited or input in the scan prescription GUI on the left screen.

Error message

Error: 200107002 Invalid event 1014 (SCAN DONE event) for current state 2000 (Idle). See Long Description for complete error. Wed Nov 22 08:55:38 2006 Error: 200107002 Host: ct01 Process: scanRx File: srx_sm_event_notify.c Line: 703 Function: Data Acquisition : OC Processing Invalid event 1014 (SCAN DONE event) for current state 2000 (Idle).

Error: 245278 Operator Paused Scanning (via Host Request) see long description for complete error Tue Sep 7 15:28:13 2010 Error: 245278 Host: ct03 Process: scanmgr File: scanmgr_events.cxx Line: 2319 Function: System Control : Scan Control Scan Type: Axial Scan: 10443/200/13 Scan Seq Id: 337000 Operator Paused Scanning (via Host Request)

Error: 200107023 A Failure had been detected while calling UIR x_ToScanRequest function or srx_sm_generate_action function See Long Description for error variations Tue Oct 19 09:22:20 2004 Error: 200107023 Host: dgct Process: scanRx File: srx_sma_manage_scan.c Line: 688 Function: Data Acquisition : OC Processing srx_sma_prepare_send_request: A Failure had been detected while calling UIRx_ToScanRequest function. Nov 22 08:55:38 2006 Error: 200107023 Host: ct01 Process: scanRx File: srx_sm_event_notify.c Line:

Applies to

Models
BrightSpeed
Product
BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
09HW30.4 For BrightSpeed Velocity See long Description 09HW30.4 For BrightSpeed Velocity {ctuser@ct01}[2] check_config sw_hw_string: 09HW30.4.HP_P_G16_G_GMV Software Collector Version 09HW30.4 p/n 5357076 5352829 - Class C (Tab# 182) 5357125 - Class M (Tab# 182)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.