GE Healthcare · CTHiSpeed
HiSpeed QX/i - Octane
Symptom
Customer reports various problems with the mouse. Any of the problems below: Mouse moves in one direction, but not the other. Mouse movement is erratic or intermittent. Mouse or the cable is physically damage. Etc. etc.
Applies to
- Models
- HiSpeed
- Product
- HiSpeed QX/i - Octane Always MDAS4 101I.2_HSQXIM5 101.4_HSQXIM4 HiSpeed QX/i - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 101I.2_HSQXIM5 101.4_HSQXIM4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2169940-28 is a 2 button PS2 mouse used on GOC1 and earlier consoles (those without HP computer). Part # 2142759 is obsolete and this 3 button mouse is a replacement. It is probable that any 3 button mouse will work in place of a 2 button mouse. 2169940-28 is a 2 button PS2 mouse used on GOC1 and earlier consoles (those without HP computer). Part # 2142759 is obsolete and this 3 button mouse is a replacement. It is probable that any 3 button mouse will work in place of a 2 button mouse. Should NOT be used on GOC2 and above or GRE consoles which contain the HP computer. The HP computer uses a 3 button mouse which is part # 2368697-2 or part # 2348405-2. 2169940-28 is a 2 button PS2 mouse used on GOC1 and earlier consoles (those without HP computer). Part # 2142759 is obsolete and this 3 button mouse is a replacement. It is probable that any 3 button mouse will work in place of a 2 button mouse. Should NOT be used on GOC2 and above or GRE consoles which contain the HP computer. The HP computer uses a 3 button mouse which is part # 2368697-2 or part # 2348405-2. Part #: 2169940-28 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: OCTANE MOUSE FRU: Yes Status: Orderable Comments: FLS - OCTANE MOUSE & INDIGO COMPUTERU/O NEXGEN 12/97 GWENN MS08992REPLACES 2114561-12 FOR (LX) LIGHTNING. PER PCN, 197770 AND FMI#60476 MUST ORDER 2187507 FOR CONTOUR SAME AS 2142759 (ALL GONE!), WHICH WAS PHASED OUT WHEN STK.WAS USED UP. MS7093 1-7-00 MOUSE AND PAD PER CHIP NLA AS HOTLINE/OBTAINFROM V/C 627584 5/1/00 MOUSE PAD IS 2252872. FE/CUSTOMER NOTE: CT ENGINEERING HAS AUTHORIZED S.G.I. TO DELIVER EITHER LIGHTOR DARK GRAY MOUSE TO FILL ORDERS FOR THIS ITEM. MS7093 HQT: M3 NEXGEN FW 10 '98 * NO LONTER STK'D @ MR MFG'RG 4-00 FOR EXCITE II SYSTEM, USE P/N 2368697-2, PER RSPL OF SAME NAME. MS20544 8/25/03. GELS - SAME AS 2142759,OCTANE MOUSE
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required