Symptom

Customer requests to have the Structured Dose Report feature turned off.

Error message

Error: 11115 Remote rejects push PACS See Long Description Thu May 20 12:50:13 2010 Error: 11115 Host: RTCT Process: dcserver File: dcspush.c Line: 1053Remote rejects push PACS

Applies to

Models
BrightSpeed
Product
BrightSpeed Select, Delight Select or MERI Select Elite-16, Edge-8, Excel-4 HP_S_G16_G_HLT HP_S_G8_G_HLT HP_S_G4_G_HLT BrightSpeed Select or Delight Select (Hivalue Lite) 4/8/16 Slice Scanner BrightSpeed Delight Select Systems started to ship in first Quarter or 2009 with AIO (All in One) Console. AIO console uses HP8400 and NO DARC or IG's. Recon time is 6 FPS. If customer orders Fluoro option system requires one IG. The 16 FPS Upgrade in Not Available for Select systems. BrightSpeed Meri Select Systems ( Pancake Das ) started to ship in 3rd quarter of 2010, 4/8/16 Slice Scanner HiValue 16 Lite −−> BrightSpeed Elite Select HiValue 8 Lite−−> BrightSpeed Edge Select HiValue 4 Lite−−> BrightSpeed Excel Select BrightSpeed Select Scope: - 3.5MHu Solarix tube - JEDI 60 dc Lite - Modified NP Table Key Features: - 16x0.625mm(16x1.25) for Lite 16 - 8x1.25/8x2.5mm for Lite 4/8 - Rotation Speed: 0.8 s - Gantry: 2040mm width, 70cm Bore - Table: 1337@ISO-140mm scannable range - Recon: 3fps (w/o IG @ 2G Memory(4/8), 4G Memory(16)), optional: 6fps(w/ 1IG ) - Power: 42KW JEDI power See the attached Service Intro Planner for details Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
09BW35.11 For BrightSpeed Meri, Discovery CT590 RT and Optima CT580 See Long Description 09BW35.11 For BrightSpeed Meri, Discovery CT590 RT and Optima CT580 Note: Installed base systems with 09BW35.11 will be upgraded to 10BW06.5 by FMI after 10BW06.5 cut in manufacturing {ctuser@ct01}[2] check_config sw_hw_string: 09BW35.11_SP1-2-1.HP_P_ P16 _G_GMV P16 = Pancake Das sw_hw_string: BSD Elite: 09BW35.11_SP1-2-1.HP_P_P16_G_GMV BSD Elite Select: 09BW35.11_SP1-2-1.HP_S_P16_G_HLT {ctuser@anonymous}[1] swhwinfo -console TRUE_IN_ONE <-- Console type identification Software Collector Version 09BW35.11 p/n 5380493 (Orderable at Coakley) OS: 5372915 CTT 6.3.10 Application: 5372914 09BW35.11 Service Pack 1-2-1: 5393041 5372916 - Class C (Tab# 182) 5372917 - Class M (Tab# 182) Additional details: Discovery CT590 RT (16 slice CT for Oncology) Optima CT580 RT (8 slice CT for Oncology) Optima CT580 W (16 slice Radiology CT for Bariatric and Interventional, etc.)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.