Pular para o conteúdo principal
GE Healthcare · CTLightSpeed2300000245001618900023000089550002

LightSpeed 4.X - GRE

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 230000024 Timeout expired waiting for the DIP to receive a buffer of views. See LD for more details Error: 230000024 Timeout expired waiting for the DIP to receive a buffer of views. Wed Mar 22 03:38:05 2006 Error: 230000024 Host: darc Process: dataacq File: dip thread.cxx Line: 612 Function: Data Acquisition : Scan Data Acquisition Scan Type: Cine Scan: 50016/6/1 Scan Seq Id: 189000 Timeout expired waiting for the DIP to receive a buffer of views. Timeout value: 250 msecs Offsets collected: 404c598h bytes Minimum offsets: 1f544c4h bytes Active data collected: 8000000h bytes Active data expected: 242eb1c8h bytes Scan aborted.

Error: 230000895 Scan Seq Id: #####View number sanity check failed: buffer number expected view number 1 actual view number 0 See Long Description for complete error: Error: 230000895 Scan Seq Id: XXXXXView number sanity check failed: buffer number expected view number 1 actual view number 0 Thu Apr 13 22:25:54 2006 Error: 230000895 Host: darc Process: dataacq File: dip_thread.cxx Line: 1422 Function: Data Acquisition : Scan Data Acquisition Scan Type: Cine Scan: 50002/1/48 Scan Seq Id: 319000View number sanity check failed: buffer number 0 expected vi

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues