Symptom

Scanner Hardware Stopped Scan with Failure reading cal file information from cal file

Error message

Error: 245201 The current scan has been aborted due to an invalid tracking calibration See Long Description for details Wed Feb 20 16:26:01 2008 Error: 245201 Host: bay44 Process: scanmgr File: scanmgr_lib.cxx Line: 682 The current scan has been aborted due to an invalid tracking calibration

Error: 230015035 Cal_db failure See LD for complete error Tue Oct 18 07:20:43 2005 Error: 230015035 Host: ctls3 Process: scanmgr File: cal_db_file_io.c Line: 762 Cal_db failure, error number = 12, reason: Not enough space Tue Sep 20 08:36:512005 Error: 230015035 Host: ls16 Process: scanmgr File: cal_db_file_io.c Line: 231 Cal_db failure, error number = 98, reason: Address already in use

Error: 230015024 A corrupt file has been found in the cal database See LD for complete error Tue Sep 20 08:36:51 2005 Error: 230015024 Host: ls16 Process: scanmgr File: cal_db_file_io.c Line: 1983 Function: CAL Processing : SBC Processing A corrupt file has been found in the cal database. The corrupt file has been removed from the cal database and saved for later analysis. Corrupt File: /usr/g/cal_db/kv120/large_sfov/16x0625/large_spot/dasgain5/cal.1.acal Saved File: /usr/g/cal_db/recovery/kv120.large_sfov.16x

Applies to

Models
BrightSpeed
Product
BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT