GE Healthcare · CTHiSpeed20000080230474187514365861185024492
Images fail to display and recon shutdown.
Symptom
Images fail to display and recon shutdown. Images fail to display and recon shutdown
Error message
Error: 200000802 Open of file for image data failed, Unix system error : 2 See long description for more details Mon Apr 2 08:25:18 2007 Error: 200000802 Host: urct Process: axialrecv File: axialrecv.c Line: 661 Image: 30474/3/32 Sequence Number:1 Open of file(/export/home1/sdc_image_pool/reserved/IMSseLBAa000RQ/E30474U0_S3U0_ I32U0.1175520318_591977) for image data failed, Unix system error : 2 --- No such file or directory. Error: 187514 RECON TIMEOUT examId:36586 seriesId:103 imageId:83 1185024492 0 1 Sat Jul 21 13:28:12 2007 187514 1 CCCT ReconJob startReconProgram.c 302 RECON TIMEOUT examId:36586 seriesId:103 imageId:83
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Software
- 10.00 HiSpeed CT HiSpeed DX/i, FX/i, LX/i, ProSpeed AI/FI, and CT/e See Long Description for details CT HiSpeed DX/i, FX/i, LX/i, ProSpeed AI/FI, and CT/e V/R 10 Release Note APPLIES TO : CT HiSpeed DX/i, FX/i, LX/i, ProSpeed AI/FI, and CT/e with system software version from V6.07 or lower PURPOSE : New version of DX/i, FX/i, LX/i, ProSpeed AI/FI, and CT/e has been released with new software called V/R10 to resolve some software bugs. This Service Note has the following purposes; To inform the service personnel (FE, ACE, RSE/ZSE and TOM), of new features, some limitations and errata and bugs which are fixed in V/R10 software. To enable the service personnel (FE, ACE, RSE/ZSE and TOM), to avoid the unnecessary visits to the site to replace components when the trouble is in fact just a bug, and to save thus the labor and money. Note: FE: Field Engineer ACE: Account Engineer RSE/ZSE: Region/Zone Support Engineer TOM: Technical Operating Manager NOTICE This Service Note is NOT intended as a handout to customers. NEVER GIVE THIS SERVICE NOTE DIRECTLY TO CUSTOMERS. PART NUMBER INFORMATION : V/R 10 Application CD–ROM: 5125861 V/R 10 Class M CD–ROM: 2308063, that is common with V6.0. SERVICE NOTES Feb. 28, 2006 Page of 5 BUG FIX : FOR V/R 10 A MR genesis image cannot be gotten from PathSpeed system or AW3.1. (PQR#13022638) When loading a Oblique protocol on Reformat Batch menu and executing [Apply], sometimes Reformat freezes. (PQR#13029610) The latest some rawdata are not displayed on ScanAnalysis, when rawdata exist about 3000. (PQR#13046339) ss(save_state) command runs incorrectly. (PQR#13022214) When customer enter WW/WL for recon2 on Film tab, the WW/WL are not set in image header. (CSO#408125) After use plural PMR (take Scout + plural PMR + Scout), AutomA cannot be set on next axial series. When CT chooses Explicit transfer syntax by association negotiation, following VR is generated as CS. Performed Procedure Step ID(0040, 0253). This VR is changed into SH in 1999 and afterwards. When selecting ”Plot” button on Manual Mode GSA after setting ”Cursor” and making no inputs for Max/Min Value, GSA will be frozen. SmartView ScreenSave image had a DICOM violation tag of (0040, 0245). It should be VR DT format, but it is set a strange string. ACS server displays an error when for this image. An user can enter 1000000 for Machine #. Referenced Standalone SOP Instance Sequence tag (0040,0220) is not sent although this tag is Type2. When Patient ID or Accession Number is entered and reentered with others, then takes scan, previous entered Patient Data are replaced with scanned Patient Data. When changing date format by reconfig, RawdataFunction’s date format is not changed. A customer can switch a desktop to ImageWorks or Display during SmartRecon, when executing ”Repeat Last Group” and ”One More Scan” after SmartRecon scan. A customer can enter ”0987654321” value for Patient Age on Patient Information display. Offline scan hangs up when entering ”0” into From and To box on Helical scan. When suck log files from a system by swHealthPage, it does not take a clipped old gesyslog. SmartPrep diagnostic scan was not started automatically, when pressing [ScanPhase] on the last scan of monitoring group. Breathe Time can be set less than a minimum Inter Scan Delay time. In Japanese and having a special annotation setting, image annotation disappear after launching installOptions. During SmartAddition reconstruction, sometimes RECON TIMEOUT happens when the last view is a spit view. Image Profile crashes by click Erase button or change WW/WL before loading image. Sometimes RECON TIMEOUT occurs on no NPRS system, when rawdata are a tube spit data on the last view and performs ”full” reconstruction. When sorting patients on SchedulePatient, patients worklist is sorted but the selected patient is wrong with displayed one. Display/Review layout was not saved by savestate and not restored during installation. PatientSchedule crashes when entering many 0 in text field next to ”Delete Completed Exam After:”, ”Day Before Today” and ”Day After Today”. If CardiacGating option is installed, Biopsy button is insensitive on Axial ViewEdit. When GraphicRetro is used in retroRecon, there is possibility that retroRecon crashes. When taking only baseline or monitoring scans and then pressing [EndExam], exam number is not increased if CTRDi is turned ON. A series w/ AutomA cannot be confirmed after SmartView series. FilmSet1:off Filmset2:on on group#4 cannot be set although previous group has Filmset1:on. RawMgr crashes when restoring rawdata and the same rawdata is being deleted at the same time. On scan data list in scan analysis, each line has a invalid week–day ”Sun”. When changing scan mode from Rotate to Stationary or from Stationary to Rotate, scan time is changed to ”1.0sec” but actually it still remains ”Sequential(All)”. In Japanese and having a special annotation setting, image annotation disappear after reconfig.
- Area
- CT