Pular para o conteúdo principal
GE Healthcare · CTLightSpeed1100214974

LightSpeed 4.X - GRE

Symptom

Cannot network / transfer images. Cannot network / transfer images

Error message

Error: 11002 DCM low level error: Network error (508): Network error (114) see long description for full error detail. Error 11002 found in gesyslog as well as other errors in /usr/g/ctuser/logfiles/dcslog gesyslog error: Thu Oct 29 14:04:48 2009 Error: 11002 Host: ct01 Process: dcserver File: dcscommon.c Line: 228 DCM low level error: Network error (508): Network error (114) dcslog errors: MESSAGE from Process 6940>> Thu Oct 29 10:01:30 2009 (dcscommon.c:228) [Dcserver]> DCM low level error: Network error (508): Network error (114) MESSAGE from Process 6940>> Thu Oct 29 10:01:30 2009 (dcspush.c:1012) Remote Host 918231UTEA is Down - Retry after next retry_interval MESSAGE from Process 14974>> Thu Oct 29 14:04:48 2009 (dcscommon.c:228) [Dcserver]> DCM low level error: Network error (508): Network error (114) MESSAGE from Process 14974>> Thu Oct 29 14:04:48 2009 (dcspush.c:1012) Remote Host 918231UTEA is Down - Retry after next retry_interval

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues