GE Healthcare · CTLightSpeed182902
LightSpeed 4.X - GRE
Symptom
Table will not move. Table will not move
Error message
Error: 182902 Emergency Off button has been pressed Sun Sep 5 16:04:39 2004 Error: 182902 Suite: RP21 Host: ETC Process: Table Controls File: tc emergency.c 1.6 2/16/99 Method: No Method line: 89 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 4016 Log Series: 22 Emergency Off button has been pressed
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-297698P3 27" HIGH PROFILE Tape switch See the LD for tape switch jpg Part #: 46-297698P3 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: 27" HIGH PROFILE BEAD, RIBBON SWITCH FRU: Yes Status: Orderable TABLE TOP COVER TAPE SWITCH. FRU = 2. *P3 WILL REPLACE THE P2 WHEN P2 STOCK IS DEPLETED. FE: IF YOU ARE REPLACING 46-297698P2 YOU MUST ORDER BOTH 2216522 AND 46-297698P3 2372372 Right Table Top Cover - used on LS 2.x - 5.x tables See LD for details 2372372 HPower Right Table Top Cover Part #: 2372372 Part Type: GP CONSUMABLES Part Weight: 72.75 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER TABLE TOP RIGHT FRU: Yes Status: Orderable Comments: FLS - COVER TABLE, TOP RIGHT. REPLACES P/N 2236720-2 ONLY ON HPOWER SYSTEMS, PER CT PCN 220864. MS20544 3/31/03. Addtional Right Table Top Cover Information: Part #: 2236720-2 <-- Use this part # for 1.x, 2.x, 3.x, 4.x and HiSpeed QXi Systems Part Type: GP CONSUMABLES Part Weight: 25.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER ASSEMBLY TABLE TOP - RIGHT FRU: Yes Status: Orderable Comments: FLS - COVER ASSEMBLY TABLE TOP-RIGHTU/O LIGHTSPEED & PET TABLE 6/30/99 MS08992 THIS REPLACED THE 2149735 PER CHRIS DOERING MSA1248 10/99 GPC TABLE MOVED TO CHINA 5/24/01 NOW ASIA SOURCED THIS P/N HAS BEEN REPLACED BY P/N 2372372 (ONLY APPLICABLE ON HPOWER SYSTEMS) PER PCN 220864. MS20544 3/31/03. DIMS: 90" LONG; 70" WIDE FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required