GE Healthcare · CTLightSpeedVCT26011202250219
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Attention: The Scanning Hardware is not available. Please see long description. Attention: The Scanning Hardware is not available, please wait for the hardware reset successfull status posted in the feature status area on the right monitor. If the hardware reset fails, then reset the scan hardware from the Service Desktop System Resets button.
Error message
Error: 260112022 Communication between the TGP and Console Pushbuttons (SCIM) are down See long description for full error Wed Sep 10 00:06:08 2008 Error: 260112022 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr_gt.c Line: 5089 Wed Sep 10 00:06:08 2008 Host : Table Gantry Processor Ermes # : 260112022 Exception Class : Secondary Severity : Pri/Soft File : uif_table_tilt_mgr_gt.c Line# : 5089 Function : No System Function Reported Scan Type : Axial Scan: 50219/1/1 Communication between the TGP and Console Pushbuttons (SCIM) are down
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5266222 Console Intercom Prescribed Tilt Hub-GOC6 See long description. 5266222 Console Intercom Prescribed Tilt Hub-GOC6 Part #: 5266222 Part Type: GP CONSUMABLES Part Weight: 2.50 KGM Repairable: No Returnable: No Hazardous Material: N Description: Console Intercom Prescribed Tilt Hub-GOC6 FRU: Yes Status: OrderableComments: Per HDVCT RSPL, 212008898, 7/15/08.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required