GE Healthcare · CTDiscovery26010500350487
Scanner Hardware Stopped Scan.
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
260105003 : (50-0243) Startup Vlength too low.Voltage has been turned off. Focal spot length affected. See LD for example 260105003 : (50-0243) Startup Vlength too low.Voltage has been turned off. Focal spot length affected. Fri Mar 19 04:43:35 2010 Error: 260105003 Host: orp Process: orp_subsys File: gen_exec.cxx Line: 2792 Fri Mar 19 04:43:35 2010 Host : Jedi Ermes # : 260105003 Exception Class : Abort Severity : Primary File : gen_exec.cxx Line# : 2792 Function : No System Function Reported Scan Type : Static Scan: 50487/1/2 . (50-0243) Startup Vlength too low.Voltage has been turned off. Focal spot length affected. Z6,Z7= 0h,0h
Applies to
- Models
- Discovery
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- D3701T : PERSEUS TUBE UNIT - Used on CT750 HD See Long Description for details. Part #: D3701T Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PERSEUS TUBE UNIT (GREEN) FRU: Yes Status: Orderable Comments: Per HDVCT RSPL, 212008898, 8/19/08. ** FE ASSIST ** Important to have adequate HV oil in the HV Wells. Making sure some oil does overflow when inserting Candle stick. (212001261 4/6/09)
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.