GE Healthcare · CT23000650323877230006523
Lightspeed 1.X - Octane
Symptom
Recon self test failure on boot up. Recon self test failure on boot up
Error message
IG selftest failed See Long description for details IG selftest failed The following errors were seen in the iceConsole.log This log file can be found in directory path /usr/g/service/log For QXi system you will find it on the sbc RECON_IG_RESET: sending reply SDC_IG_INTF: <<<aborting...>>> IC Proxy - received an abort process 0 has no error process 1 has no error process 2 has no error process 3 has no error process 4 has no error process 5 has no error process 6 has no error RECON_IG_RESET: sending reply RECON_IG_RESET: sending reply RECON_IG_RESET: sending reply IG selftest failed DSP1 failed =0x100 DSP3 failed =0x900 DSP4 failed =0x800 DSP5 failed =0x800 DSP6 failed =0x800 DSP7 failed =0x800 Selftest failed Error: 230006503 Cannot send abort successfully. It could be caused by ice box. See Long Description Wed Nov 10 15:26:28 2010 Error: 230006503 Host: ct01_sbc Process: reconmgr File: rm_recon_events.c Line: 567 Function: Image Generation : SBC Processing Job Type: Prospective Helical Scan: 23877/2/1 Image: 23877/2/89 Recon Seq Id: 180 Cannot send abort successfully. It could be caused by ice box. Error: 230006523 Attempting Recon Subsystem Reset See long description Fri May
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required