Pular para o conteúdo principal
GE Healthcare · CTHiSpeed200900025

HiSpeed QX/i - Octane

Symptom

Connect Pro Modality Work List will not update. Connect Pro Modality Work List will not update

Error message

Error: 200900025 Parse Failed : Invalid Worklist received from remote HIS(xxxx)(xxxx) :-xxx Note in the error example above that the error is referring to dicom tag number 0010 2154 . The numbers shown in this location of an error message like this will have the leading zeroes stripped off on tags that have leading zeroes such as the example shown. Thu Sep 28 00:01:23 2006 Error: 200900025 Host: gect1 Process: WLServer File: WLapiSystem.c Line: 191 Function: Data Management : OC Processing Patient Worklist Manager error Source File: WLS_mfm.c, Line: 1465, Status: 23 Parse Failed : Invalid Worklist received from remote HIS (10)(2154) :-113 Tue Sep 13 18:13:04 2011 Error: 200900025 Host: LS16 Process: WLServer File: WLapiSystem.c Line: 191 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLS_mfm.c, Line: 1471, Status: 23 Parse Failed : Invalid Worklist received from remote HIS(32)(1060) :-114

Applies to

Models
HiSpeed
Product
HiSpeed QX/i - Octane Always MDAS4 101I.2_HSQXIM5 101.4_HSQXIM4 HiSpeed QX/i - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 101I.2_HSQXIM5 101.4_HSQXIM4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
101I.2_HSQXIM5 See LD for ClassM & C 101I.2_HSQXIM5 used on HiSpeed (YMS) only Class M software - 2395173 or 2401759 (6 pack) Class C software - 2395172 or 2401759 (6 pack) Patch G.6 Mandatory FMI# 25363 (P/N 5136941)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required