GE Healthcare · CTBrightSpeed26010001914111
BrightSpeed HPower, Delight, Velocity or MERI HPower
Symptom
Missed ISD See Long Description Inter Scan Delay ISD Missed .
Error message
Error: 260100019 ISD missed Fri Nov 21 19:19:11 2008 Error: 260100019 Host: tgp Process: tgp_subsys File: scTrigSeqActions.c Line: 1163 Fri Nov 21 19:19:11 2008 Host : Table Gantry Processor Ermes # : 260100019 Exception Class : Secondary Severity : Pri/Soft File : scTrigSeqActions.c Line# : 1163 Function : No System Function Reported Scan Type : Axial Scan: 2/3/2 ISD missed. Rx ISD: 1299 mS Actual ISD: 14111 More Data Follows: (Cur Rx: Ax:1000 Kv:120 mA:20 Fil:1 GOpt:0x8 Freq:984 Ex/Opt:44/1 Prev Rx: Ax:1000 Kv:120 mA:20 Fil:1 GOpt:0x8 Freq:984 Ex/Opt:0/1)
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2339120 Cradle drive assembly See long decription for details Part #: 2339120 Part Type: GP REPAIRABLES Part Weight: 2.20 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: CRADLE DRIVE ASSY - H PWR FRU: Yes Status: Orderable Comments: FLS - CRADLE DRIVE ASSY - H PWR. ADDED PER HPOWER PROGRAM RSPL BY MS20544 ON 2/24/03. POSSIBLE M3 DATE: FW19, 2003.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required